Com Data
for Modbus
SECTION 6 Communications Data for Modbus
6-16
Address
Parameter name Setting (monitor) value LevelFour-
byte
mode
Two-
byte
mode
1356 332B Manual MV Limit Ena-
ble
H'00000000 (0): OFF
H'00000001 (1): ON
Advanced
function
setting
135A 332D PV Rate of Change
Calculation Period
H'00000001 to H'000003E7 (1 to 999)
135C 332E Automatic Cooling
Coefficient Adjust-
ment
H'00000000 (0): OFF
H'00000001 (1): ON
135E 332F Heater Overcurrent
Use
H'00000000 (0): OFF
H'00000001 (1): ON
1360 3330 Heater Overcurrent
Latch
H'00000000 (0): OFF
H'00000001 (1): ON
1362 3331 Heater Overcurrent
Hysteresis
H'00000001 to H'000001F4 (0.1 to 50.0)
1364 3332 Control Output 1 ON/
OFF Count Alarm Set
Value
H'00000000 to H'0000270F (0 to 9999)
1366 3333 Control Output 2 ON/
OFF Count Alarm Set
Value
H'00000000 to H'0000270F (0 to 9999)