G3PA-(VD)
G3PA-(VD)
144
Linking Terminal Connection
Connecting with linking terminal for G3PA-210B-VD,
-220B-VD,
-240B-VD and G3P
A-420B-VD, G3P
A-430B-VD.
1. When SSRs are close
mounted, loosen the
M3.5 Sems screw and
flip the linking terminal
down.
2. Insert the linking
terminal securely
into the center of
the screw and
tighten
the screw
.
SSR1 SSR2 SSR1 SSR2
Connecting
with linking terminal for G32A.
1. When SSR are close
mounted, loosen the
M3.5 Sems screw on
the G32A and flip the
linking
terminal down.
2. Insert
the linking termi
-
nal securely into the
center
of the screw and
tighten the screw. En-
sure that the linking
terminal does not pro-
trude.
SSR G32A Unit SSR G32A Unit
*
* The cover will not fit if
the terminal protrudes.
Linking terminal
Linking terminal
Linking
terminal
Linking
terminal
Connect
the terminal with power of
f.
Refer to the instruction manual for
the G32A-A Power Device Cartridge
to replace the G3PA
s triac part.
When the temperature indicator has turned from pink to red, the G32-A-A Power Device Car-
tridge may have malfunctioned, in which case the cartridge must be replaced with a new one.
Use the terminal cover to prevent accidents
due to electric shock.
G3PA-420B-VD