Setting Item Table
Mode Setting item Discription Setting procedure
Run mode Set value Compared to the present value.
Determines the timing of the
control output according to the
output mode.
Sequence when changing a digit using the incre-
ment
keys (1 to 4).
012 89
Batch count set
value
Turns ON the batch output when
the preset number of cycles have
been completed.
Sequence when changing a digit using the incre-
ment
keys (1 to 4).
012 89
Setting mode Time range* Determines the timing range.
Change the timing range with the increment keys (1 to 4).
UP/DOWN mode Selects
Select UP/DOWN with the increment keys (1 to 4).
(UP) (DOWN)
ud
Output mode Determines the form of the control
output. (Refer to the present value
vs. output diagrams on page 10 to
12.)
S
equence w
h
en c
h
ang
i
ng t
h
emo
d
eus
i
ng t
h
e
i
ncrement
keys (1 to 4).
a a -- 1 a -- 2 a -- 3 b b -- 1 d e f
Output time Determines the duration of the
control output.
Will be displayed when the output
mode is A, A-1, A-2, A-3, b, or
b-1. Will not be displayed when
the output mode is d, E, or F.
Use keys 1 to 3 to change the value.
Key1 adjusts the first digit (0.1’s digit).
Key2 adjusts the second digit (1’s digit).
Key3 adjusts the third digit (10’s digit).
Key4 selects either hold output or one-shot output.
012 89
hold 0 0
.s
Input signal time Changes the duration of the
control and reset input signals.
Change the duration with the increment keys (1 to 4).
(1 ms) (20 ms)
120
Key protect level Locks certain keys to prevent
accidental operation. The key
protection level, kP-1 to kP-4,
determines which keys are locked
when the key protection input is
ON. The locked keys are crossed
out in the diagram on the right.
Sequence when changing the key protect level using the
increment keys (1 to 4).
412 3
p
p p p
<KP--1> <KP--2>
<KP--3><KP--3>
Note: 1. Changes made in setting mode become effective when run mode is entered.
2. The time range setting appears first when setting mode is entered.

Other manuals for Omron H3CR-A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron H3CR-A and is the answer not in the manual?

Omron H3CR-A Specifications

General IconGeneral
Time Range0.05 seconds to 300 hours
Output TypeRelay
Mounting TypeDIN Rail
Operating Temperature-10°C to 55°C
Contact FormSPDT
Number of Pins8
Contact Rating5A at 250VAC
Storage Temperature-25°C to 65°C
TypeSolid State Timer
Dimensions48 mm x 48 mm
Operating ModeON-delay, OFF-delay, Interval, One-shot
Operating Voltage24V DC, 100-240V AC