Preset Counter/Timer
H8GN
C-63
Counters
■
Characteristics
Note:
Refer to the
Life-test Curve
.
Timer function Accuracy of operating
time and setting error
(including temperature
and voltage effects)
Signal start:
±
0.03%
±
30 ms max.
Power-ON start:
±
0.03%
±
50 ms max.
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Dielectric strength
1,500 VAC, 50/60 Hz for 1 min between output terminals and non-current-carrying metal
parts
510 VAC, 50/60 Hz for 1 min between current-carrying terminals (except output terminals)
and non-current-carrying metal parts
1,500 VAC, 50/60 Hz for 1 min between output terminals and current-carrying terminals (ex-
cept output terminals)
500 VAC, 50/60 Hz for 1 min between communications terminals and current-carrying termi-
nals (except output terminals)
1,000 VAC, 50/60 Hz for 1 min between contacts not located next to each other
Noise immunity
Square-wave noise by noise simulator;
±
480 V (between power terminals),
±
600 V (between input terminals)
Static immunity
±
8 kV (malfunction),
±
15 kV (destruction)
Vibration resistance Malfunction
10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min
Destruction
10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h
Shock resistance Malfunction
100 m/s
2
, 3 times each in six directions
Destruction
300 m/s
2
, 3 times each in six directions
Life expectancy Mechanical
10 million operations
Electrical
100,000 operations min. (3 A at 250 VAC, resistive load) (See note.)
Ambient temperature Operating
−
10
°
C to 55
°
C (with no icing or condensation)
Storage
−
25
°
C to 65
°
C (with no icing or condensation)
Ambient humidity
25% to 85%
EMC
(EMI): EN61326
Emission Enclosure: EN55011 Group 1 Class A
(EMS): EN61326
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated,
80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated,
900 MHz
±
5 MHz) (level 3)
Immunity Conducted
Disturbance: EN61000-4-6: 3 V (0.15 to 80 MHz) (level 2)
Immunity Burst: EN61000-4-4: 2 kV power-line (level 3);
1 kV I/O signal-line (level 4);
1 kV communications-line (level 3)
Immunity Surge: EN61000-4-5: 1 kV between lines
(power and output lines) (level 3);
2 kV between grounds
(power and output lines) (level 3)
Approved standards
UL508, CSA C22.2 No.14
Conforms to EN61010-1/IEC61010-1 (Pollution degree 2/overvoltage category
II
)
Conforms to VDE0106/P 100 (Finger Protection)
Case color
Rear section: Gray smoke; Front section: N1.5 (black)
Degree of protection
Panel surface: IP66 and NEMA Type 4X (indoors)
Rear case: IP20
Terminal block: IP20
Weight
Approx. 80 g