EasyManua.ls Logo

Omron HEM-7155-E(C) - User Manual

Omron HEM-7155-E(C)
17 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
New Product Information Sheet
Specifications subject to change
© OMRON HEALTHCARE EUROPE B.V.
Model (code):
M3 Comfort (HEM-7155-E(C))
Versions
Remark
Date
1
Complete NPIS
17.11.2021
Question and Answer IconNeed help?

Do you have a question about the Omron HEM-7155-E(C) and is the answer not in the manual?

Summary

Product Information

M3 Comfort Model Details

Identifies the specific OMRON M3 Comfort blood pressure monitor model.

Product Features and Packaging

Key Features

Highlights Intelli Wrap Cuff, Irregular Heartbeat Detection, user memory, and clinical validation.

Packaging Contents and Logistics

Lists package contents, logistic information, and storage/transport conditions.

Technical Specifications

Measurement and Accuracy

Details blood pressure/pulse ranges, accuracy, inflation, and deflation methods.

Device Operation and Power

Covers operating mode, IP classification, power source, battery life, and durable period.

Environment and Protection

Specifies operating conditions, storage/transport conditions, and protection against.

Product Description and Usage

General Description and Purpose

Explains the oscillometric method, device purpose, and application field.

Intended User and Indications

Defines the target user and specific indications for using the device.

Features and Device Use

Key Features and Operating Principle

Summarizes key features and describes the oscillometric operating principle.

How to Use the Device

Provides step-by-step instructions for taking blood pressure measurements.

Materials and Manuals

Accessory Materials and Manuals

Details materials used for accessories and shows instruction manual title pages.

Package Design Illustration

Unfolded Package Layout

Illustrates the unfolded package design of the main device and its accessories.

Accessory Details

Arm Cuff and AC Adapter Information

Provides details and specifications for the Arm Cuff (HEM-FL31) and AC Adapter (HHP-CM01).

AC Adapter and Standards Compliance

AC Adapter (HHP-BFH01) and EN Standards

Details the AC Adapter (HHP-BFH01) and lists the harmonized EN standards.

Device Operation and Care

Cleaning and Maintenance

Instructions for cleaning the device and notes on maintenance requirements.

Storage Guidelines

Provides instructions for safely storing the monitor and its components.

Safety Warnings

General Safety and Usage Warnings

Covers essential warnings for device usage, medication, and health conditions.

Child Safety Precautions

Highlights warnings related to keeping the product and its parts away from children.

Handling and Cautions

AC Adapter and Battery Handling

Safe handling procedures for the AC adapter and batteries.

User Cautions and Best Practices

Cautions for users regarding skin irritation, medical conditions, and electromagnetic interference.

Usage Guidelines and Precautions

Operational Restrictions and Environment

Covers restrictions on usage environments, vehicles, and with other equipment.

Measurement Preparation and Accessory Use

Instructions for measurement preparation and emphasizing accessory compatibility.

Additional Handling and Precautions

Specific Handling and Disposal

Details on handling AC adapters, batteries, and correct product disposal methods.

General Measurement Precautions

Precautions for taking measurements, including arm selection and tube placement.

Product Lifecycle Management

Disposal, Storage, and Transport

Guidance on product disposal, storage conditions, and transport requirements.

Warranty and Repair Information

Details on warranty periods for monitor, cuff, adapter, and information on repair services.

Service and Support

Warranty Service and Customer Contact

Information on warranty service, finding customer support, and contact details.

Manufacturer and Representative Information

Lists the legal manufacturer, production facility, and EU representative details.

Summary

Product Information

M3 Comfort Model Details

Identifies the specific OMRON M3 Comfort blood pressure monitor model.

Product Features and Packaging

Key Features

Highlights Intelli Wrap Cuff, Irregular Heartbeat Detection, user memory, and clinical validation.

Packaging Contents and Logistics

Lists package contents, logistic information, and storage/transport conditions.

Technical Specifications

Measurement and Accuracy

Details blood pressure/pulse ranges, accuracy, inflation, and deflation methods.

Device Operation and Power

Covers operating mode, IP classification, power source, battery life, and durable period.

Environment and Protection

Specifies operating conditions, storage/transport conditions, and protection against.

Product Description and Usage

General Description and Purpose

Explains the oscillometric method, device purpose, and application field.

Intended User and Indications

Defines the target user and specific indications for using the device.

Features and Device Use

Key Features and Operating Principle

Summarizes key features and describes the oscillometric operating principle.

How to Use the Device

Provides step-by-step instructions for taking blood pressure measurements.

Materials and Manuals

Accessory Materials and Manuals

Details materials used for accessories and shows instruction manual title pages.

Package Design Illustration

Unfolded Package Layout

Illustrates the unfolded package design of the main device and its accessories.

Accessory Details

Arm Cuff and AC Adapter Information

Provides details and specifications for the Arm Cuff (HEM-FL31) and AC Adapter (HHP-CM01).

AC Adapter and Standards Compliance

AC Adapter (HHP-BFH01) and EN Standards

Details the AC Adapter (HHP-BFH01) and lists the harmonized EN standards.

Device Operation and Care

Cleaning and Maintenance

Instructions for cleaning the device and notes on maintenance requirements.

Storage Guidelines

Provides instructions for safely storing the monitor and its components.

Safety Warnings

General Safety and Usage Warnings

Covers essential warnings for device usage, medication, and health conditions.

Child Safety Precautions

Highlights warnings related to keeping the product and its parts away from children.

Handling and Cautions

AC Adapter and Battery Handling

Safe handling procedures for the AC adapter and batteries.

User Cautions and Best Practices

Cautions for users regarding skin irritation, medical conditions, and electromagnetic interference.

Usage Guidelines and Precautions

Operational Restrictions and Environment

Covers restrictions on usage environments, vehicles, and with other equipment.

Measurement Preparation and Accessory Use

Instructions for measurement preparation and emphasizing accessory compatibility.

Additional Handling and Precautions

Specific Handling and Disposal

Details on handling AC adapters, batteries, and correct product disposal methods.

General Measurement Precautions

Precautions for taking measurements, including arm selection and tube placement.

Product Lifecycle Management

Disposal, Storage, and Transport

Guidance on product disposal, storage conditions, and transport requirements.

Warranty and Repair Information

Details on warranty periods for monitor, cuff, adapter, and information on repair services.

Service and Support

Warranty Service and Customer Contact

Information on warranty service, finding customer support, and contact details.

Manufacturer and Representative Information

Lists the legal manufacturer, production facility, and EU representative details.

Overview

The OMRON M3 Comfort (HEM-7155-E(C)) is an automatic upper arm blood pressure monitor designed for general household use. It utilizes the oscillometric method of blood pressure measurement, detecting blood movement through the brachial artery and converting these movements into a digital reading. This device is clinically validated for use in general populations, as well as for pregnant individuals and those with diabetes.

Function Description:

The M3 Comfort measures blood pressure (SYS 60 to 260 mmHg, DIA: 40 to 215 mmHg) and pulse rate (40 to 180 beats/min) in adult patients. It features irregular heartbeat detection, alerting the user during a reading if an irregular heartbeat is detected. The device also includes a cuff wrap guide to ensure the cuff is wrapped correctly for accurate results. It stores up to 60 readings per user for two users, and also offers a guest mode. The monitor operates in continuous operation mode.

Important Technical Specifications:

  • Model Code: M3 Comfort (HEM-7155-E(C))
  • Measurement Method: Oscillometric method
  • Display: LCD digital display
  • Cuff Pressure Range: 0 to 299 mmHg
  • Blood Pressure Measurement Range: SYS 60 to 260 mmHg, DIA: 40 to 215 mmHg
  • Pulse Measurement Range: 40 to 180 beats/min
  • Accuracy: Pressure ± 3mmHg, Pulse ± 5% of display reading
  • Inflation: Automatic by electric pump
  • Deflation: Automatic pressure release valve
  • IP Classification: Monitor: IP 20; Optional AC adapter: IP21
  • Rating: DC6 V 4.0 W
  • Applied Part: Type BF (arm cuff)
  • Power Source: 4 "AA" batteries 1.5 V or optional AC adapter (input AC 100-240 V 50-60 Hz 0.12 -0.065 A)
  • Battery Life: Approximately 1000 measurements (using new alkaline batteries)
  • Durable Period (Service Life): Monitor: 5 years; Cuff: 5 years; Optional AC adapter: 5 years
  • Operating Conditions: +10 to +40 °C / 15 to 90% RH (non-condensing) / 800 to 1060 hPA
  • Storage / Transport Conditions: -20 to +60 °C / 10 to 90% RH (non-condensing)
  • Protection against electric shock: Internally powered ME equipment (when using only batteries) Class II ME equipment (optional AC adapter)
  • Dimensions (approximate value): Monitor: 105 mm (W) × 85 mm (H) × 152 mm (L); Arm cuff: 145 mm × 532 mm (air tube: 750 mm)
  • Weight (approximate value): Monitor: 340 g (not including batteries); Arm cuff: 163 g
  • Materials:
    • Main Unit Housing, Battery Cover, Front Panel, Button: ABS (acrylonitrile butadiene styrene)
    • Package: Coated board
    • Instruction Manual: Paper
    • Cuff (Cloth, fabric): Nylon, PVC (Polyvinyl Chloride)
    • Cuff (Air Tube): PVC (Polyvinyl Chloride)
    • Cuff (Air plug to device): ABS (acrylonitrile butadiene styrene)
    • Cuff (Air plug to cuff): PC (Polycarbonate)
    • AC Adapter (DC Cord): PVC (Polyvinyl Chloride)
    • AC Adapter (Print case): PPE (Polyphenylene Ether)

Usage Features:

The device comes with an Intelli Wrap Cuff (HEM-FL31) designed to provide accurate results in any position around the upper arm. It supports two users with 60 memories each, plus a guest mode. A cuff wrap guide helps ensure correct cuff application. The monitor is supplied with 4 "AA" batteries, a storage case, and two instruction manuals. Optional accessories include an AC adapter (HHP-CM01) and an AC Adapter UK version (HHP-BFH01).

To use the device:

  1. Prepare for measurement: Avoid alcohol, smoking, hot showers, hot beverages, eating, or exercising 30 minutes prior. Relax for 5 minutes before.
  2. Install batteries.
  3. Set the date and time.
  4. Apply the arm cuff on the left arm (or right arm, consulting IM1 Chapter 2.3).
  5. Sit correctly, place the arm at heart level, remain still, and avoid talking.
  6. Select user ID.
  7. Take the measurement by pressing the START/STOP button.
  8. Check readings, consulting IM2 Section 9 for symbol explanations.
  9. Utilize memory functions (stored readings, average of latest 2-3 readings, clear memory) after selecting a user ID.

Maintenance Features:

  • Cleaning: The device should be cleaned with a soft dry cloth or a soft cloth moistened with neutral soap. Abrasive or volatile cleaners, gasoline, thinners, or similar solvents should not be used. The monitor and arm cuff should not be washed or immersed in water.
  • Regular Maintenance: This device does not require any regular maintenance.
  • Storage: When not in use, store the monitor in its storage case. Remove the arm cuff from the monitor by pulling on the plastic air plug at the base of the tube. Gently fold the air tube into the arm cuff, avoiding excessive bending or creasing. Store the monitor and components in a clean, safe location, away from extreme temperatures, humidity, direct sunlight, dust, corrosive vapors, vibrations, shocks, or angled positions. Ensure the device is dry before storage.
  • Servicing: The accuracy of the blood pressure monitor is carefully tested. It is recommended to have the unit inspected every two years to ensure correct functioning and accuracy. Consult an authorized OMRON dealer or OMRON Customer Service for servicing.
  • Warranty: The monitor has a 3-year warranty, while the cuff and optional AC adapter have a 1-year warranty. The service life for the monitor, cuff, and AC adapter is 5 years. Warranty is granted only if the complete product is returned with the original invoice/cash ticket.
  • Disposal: Household users should contact their retailer or local government office for environmentally safe recycling instructions.

Omron HEM-7155-E(C) Specifications

General IconGeneral
BrandOmron
ModelHEM-7155-E(C)
CategoryBlood Pressure Monitor
LanguageEnglish

Related product manuals