16.3. Change the Device and Version elds, shown below, to match the HMI panel that you are currently
using.
16.4. Open the HMI menu and select Communications Setup as shown below.
16.5. Click the Ethernet connection via a hub button as shown below.
16.6. In the Specify IP Address eld, enter the IP address for the NA-HMI panel. The default address for an
NA-HMI panel, port 1, is: 192.168.250.2.
16.7. Click "Test".
16.8. Be sure Test OK” shows in the white bar as shown below. This will indicate you have good
communications with the Omron controller.
16.9. Click "OK" when ready.