3 Error Tables
3-180
NJ-series Troubleshooting Manual (W503)
90090000 hex Variable Changed to FALSE with
Forced Refreshing
Errors Related to Controller Opera-
tion
W500, W501
900A0000 hex All Forced Refreshing Cleared Errors Related to Controller Opera-
tion
W500, W501
900B0000 hex Memory All Cleared Errors Related to Controller Opera-
tion
W500, W501
900C0000 hex Event Log Cleared Errors Related to Controller Opera-
tion
W500, W501
900F0000 hex* Automatic Transfer Completed Errors Related to Controller Opera-
tion
W500, W501
90110000 hex Power Turned ON Errors Related to Controller Opera-
tion
W500, W501
90120000 hex Power Interrupted Errors Related to Controller Opera-
tion
W500, W501
90130000 hex Operation Started Errors Related to Controller Opera-
tion
W500, W501
90140000 hex Operation Stopped Errors Related to Controller Opera-
tion
W500, W501
90150000 hex Reset Executed Errors Related to Controller Opera-
tion
W500, W501
90160000 hex User Program Execution ID Write Errors Related to Controller Opera-
tion
W500, W501
90180000 hex All Controller Errors Cleared Errors Related to Controller Opera-
tion
W500, W501
90190000 hex Forced Refreshing Cleared Errors Related to Controller Opera-
tion
W500, W501
901A0000 hex* Backup Started Errors Related to Controller Opera-
tion
W500, W501
901B0000 hex* Backup Completed Errors Related to Controller Opera-
tion
W500, W501
901C0000 hex* Restore Operation Started Errors Related to Controller Opera-
tion
W500, W501
901D0000 hex* Restore Operation Completed Errors Related to Controller Opera-
tion
W500, W501
90400000 hex* Event Log Cleared NX-series EtherCAT Coupler Unit,
NX-series Digital I/O Units, NX-series
Analog I/O Units, NX-series System
Units, NX-series Position Interface
Units, and NX-series Safety Control
Unit
W519, W521,
W522, W523,
W524, and
Z930
90420000 hex* Restart Executed NX-series EtherCAT Coupler Unit W519
90430000 hex* Memory All Cleared NX-series EtherCAT Coupler Unit
and NX-series Safety Control Unit
W519, Z930
94010000 hex Tag Data Link Download Started Built-in EtherNet/IP Port on CPU Unit W506
94020000 hex Tag Data Link Download Finished Built-in EtherNet/IP Port on CPU Unit W506
94030000 hex Tag Data Link Stopped Built-in EtherNet/IP Port on CPU Unit W506
94040000 hex Tag Data Link Started Built-in EtherNet/IP Port on CPU Unit W506
94050000 hex Link Detected Built-in EtherNet/IP Port on CPU Unit W506
94060000 hex Restarting Ethernet Port Built-in EtherNet/IP Port on CPU Unit W506
94070000 hex Tag Data Link All Run Built-in EtherNet/IP Port on CPU Unit W506
94080000 hex IP Address Fixed Built-in EtherNet/IP Port on CPU Unit W506
94090000 hex BOOTP Client Started Built-in EtherNet/IP Port on CPU Unit W506
Event code Event name Functional classification Reference

Table of Contents

Other manuals for Omron NJ Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NJ Series and is the answer not in the manual?

Omron NJ Series Specifications

General IconGeneral
Program CapacityUp to 128 MB
SD Card SlotYes
Power Supply Voltage24 VDC
Motion ControlYes
USB Ports1
Operating Temperature0°C to 55°C
Communication InterfacesEthernet/IP, EtherCAT, USB
Safety FunctionOptional
Storage Temperature-20°C to 75°C
Communication PortsUSB
DimensionsVaries by model
WeightVaries by model