3 Error Tables
3-30
NJ-series Troubleshooting Manual (W503)
54015440 hex Axes Group Can-
not Be Enabled
Execution of the
MC_GroupEnable (Enable
Axes Group) instruction
failed.
When the
MC_GroupEnable
(Enable Axes Group)
instruction was exe-
cuted, there was a
composition axis that
was not stopped.
When the
MC_GroupEnable
(Enable Axes Group)
instruction was exe-
cuted, there was a
composition axis for
which the
MC_TouchProbe
(Enable External
Latch) instruction was
being executed.
S NJ-series
Instruc-
tions Ref-
erence
Manual
(Cat. No.
W502)
54015441 hex Impossible Axis
Operation Speci-
fied when the
Servo is OFF
An operation instruction
was executed for an axis for
which the Servo is OFF.
An operation instruc-
tion was executed for
an axis for which the
Servo is OFF.
Home was preset with
the MC_Home or
MC_HomeWithParam
eter instruction for an
axis for which Ether-
CAT process data
communications are
not established.
S Same as
above.
54015442 hex Composition Axis
Stopped Error
A motion instruction was
executed for an axes group
while the MC_Stop instruc-
tion was being executed for
a composition axis.
A motion instruction
was executed for an
axes group while the
MC_Stop instruction
was being executed
for a composition axis.
S Same as
above.
54015443 hex Motion Control
Instruction Multi-
execution Buffer
Limit Exceeded
The number of motion con-
trol instructions that is buff-
ered for Buffered or
Blending Buffer Modes
exceeded the buffer limit.
An axis instruction
was executed when
there was already a
current instruction and
a buffered instruction
for the same axis.
An axes group instruc-
tion was executed
when there was
already eight current
instructions and buff-
ered instructions for
the same axis.
S Same as
above.
54015444 hex Insufficient Travel
Distance
The specified motion can-
not be executed for the
deceleration rate or accel-
eration rate that was speci-
fied for multi-execution or
re-execution of a position-
ing instruction.
Stopping at the target
position was not pos-
sible for the specified
acceleration/decelera-
tion rate for multi-exe-
cution or re-execution
of a positioning
instruction when the
Acceleration/Deceler-
ation Over parameter
was set to generate a
minor fault and stop.
S Same as
above.
Event code Event name Meaning Assumed cause
Level
Refer-
ence
Maj Prt Min Obs Info

Table of Contents

Other manuals for Omron NJ Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NJ Series and is the answer not in the manual?

Omron NJ Series Specifications

General IconGeneral
Program CapacityUp to 128 MB
SD Card SlotYes
Power Supply Voltage24 VDC
Motion ControlYes
USB Ports1
Operating Temperature0°C to 55°C
Communication InterfacesEthernet/IP, EtherCAT, USB
Safety FunctionOptional
Storage Temperature-20°C to 75°C
Communication PortsUSB
DimensionsVaries by model
WeightVaries by model