NXR-ILM08C-EIT
7
General Specifications
*1. Refer to the OMRON website (www.ia.omron.com) or ask your OMRON representative for the most recent applicable standards for each
model.
Item Specification
Degree of protection IP67
Operating
environment
Ambient operating temperature -10 to 55°C
Ambient operating humidity 25% to 85% (with no condensation)
Ambient operating atmosphere Must be free from corrosive gases.
Storage temperature -25 to 65°C
Storage humidity 25% to 85% (with no condensation)
Altitude 2,000 m max.
Pollution degree 3 or less: Conforms to IEC 61010-2-201.
Noise immunity 2 kV on power supply line (Conforms to IEC 61000-4-4.)
Overvoltage category Category II: Conforms to IEC 61010-2-201.
EMC immunity level Zone B
Vibration resistance
10 to 60 Hz with amplitude of 0.35 mm, 60 to 150 Hz and 50 m/s
2
for 80 minutes each in X, Y, and Z directions.
Shock resistance 150 m/s
2
, 3 times each in 6 directions along X, Y, and Z axes
Dielectric strength 600 VAC (between isolated circuits)
Insulation resistance 20 MΩ min. (between isolated circuits)
Applicable standards *1 EU: EN 61131-2, RCM, KC, IO-Link conformance, EtherNet/IP conformance