Appendices
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
A-3 Sysmac Error Status Codes
A
A-3-1 Error Table
0806 0000
hex
External
Encoder
Error
Warning
The external encoder
detected a warning.
There is insufficient
external encoder power
supply voltage.
Noise is entering on the
external encoder
connector cable.
The external encoder
failed.
3 P.A-160
0807 0000
hex
External
Encoder
Communications
Warning
The external encoder
had more
communications
errors than the
specified value.
There is insufficient
external encoder power
supply voltage.
Noise is entering on the
external encoder
connector cable.
3 P.A-161
34E0 0000
hex
Data Setting
Warning
An object setting is out
of range.
An object setting is out of
range.
3 P.A-161
383C 0000
hex
Overload
Warning
The load ratio is 85%
or more of the
protection level.
Overload
There is incorrect wiring of
the motor line or a broken
cable.
3 P.A-162
383D 0000
hex
Excessive
Regeneration
Warning
The regeneration load
ratio is 85% or more of
the level.
There is excessive
regeneration.
This Regeneration Resistor
cannot be used for
continuous regenerative
braking.
3 P.A-163
383E 0000
hex
Vibration
Detection
Warning
Vibration was
detected.
The gain or mass ratio
setting is not suitable.
3 P.A-164
7480 0000
hex
Command
Warning
A command could not
be executed.
A forced brake operation
request was sent while the
servo was ON.
When 3508 hex is “0,”
Switch ON command was
sent when the main power
was OFF.
An Enable Operation
command was sent to
request turning ON the
Servo when the motor was
operating at 30 mm/s or
higher.
A latch operation was
started when the Config
operation was being
performed.
A latch operation was
started when the
Statusword (6041 hex) bit
9 (Remote) was 0 (local).
An operation command is
given in the prohibited
direction after the motor
made an immediate stop
due to a drive prohibition
input.
3 P.A-165
Event
code
Event name Description Assumed cause
Level
Reference
Maj
Prt
Min
Obs
Info

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-KN10F-ECT-L and is the answer not in the manual?

Omron R88D-KN10F-ECT-L Specifications

General IconGeneral
BrandOmron
ModelR88D-KN10F-ECT-L
CategoryServo Drives
LanguageEnglish

Related product manuals