Page #314 background imageLoading...
Page #314 background image
4-45
4-3 Wiring Conforming to EMC Directives
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
4
System Design
Radio Noise Filter and Emission Noise Prevention Clamp Core
Use one of the following filters to prevent switching noise of PWM of the Servo Drive and to
prevent noise emitted from the internal clock circuit.
*1. Generally used for 1.5 kW or higher.
*2. Generally used for 1.5 kW or lower. The maximum number of windings is 3 turns.
*3. Generally used for 50/100 W. The maximum number of windings is 2 turns.
*4. Also used on the Drive output power lines to comply with the EMC Directives. Only a clamp is used.
This clamp can also be used to reduce noise current on a FG line.
Model Manufacturer Application
3G3AX-ZCL1
*1
OMRON For Drive output and power cable
3G3AX-ZCL2
*2
OMRON For Drive output and power cable
ESD-R-47B
*3
NEC TOKIN For Drive output and power cable
ZCAT3035-1330
*4
TDK For Encoder cable and I/O cable
RJ8035 Konno Industry For power lines
RJ8095 Konno Industry For power lines
T400-61D MICROMETALS For Servo Drive output and power cables

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-KT50F and is the answer not in the manual?

Omron R88D-KT50F Specifications

General IconGeneral
BrandOmron
ModelR88D-KT50F
CategoryServo Drives
LanguageEnglish