12-30
12-2 Parameter List
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
  12
Appendix
528 Default Display
29 Drive serial number
1
−
0 to 35 Yes
30 Motor serial number −
31 Accumulative operation time h
32 Automatic Motor Recognition Function −
33 Temperature Information °C
35 Safety status monitor −
531 Axis Number
Set the axis number for USB 
communications. Normally, do not change 
the set value.
1 − 0 to 127 Yes
532
Command Pulse 
Input Maximum 
Setting
Set the maximum command pulse input.
4000 kpps
250 to 
4,000
Yes
533
Pulse 
Regeneration 
Limit Output 
Setting
Set the detection of pulse regeneration limit error.
0 − 0 or 1 Yes0 Disabled
1 Enabled
535
Front Key 
Protection 
Setting
Set the operation limit for the front panel.
0 − 0 or 1 Yes0 Operation not blocked
1 Operation blocked
Pn number
Parameter 
name
Description
Default 
setting
Unit
Setting 
range
Power 
supply 
OFF to 
ON