171
Temperature Input Units Section 6-4
Names and Functions of Parts
LED Indicators
TS Indicator The TS indicator shows the status of the Slice I/O Unit itself. Refer to 2-1-3
LED Indicators for details. (For the GRT1-TS2T only, the indicator will flash
red if an error occurs in the cold junction compensator.)
ERR Indicators The ERR indicators show input errors.
007301C0
SER. No.
Terminal Block
The serial number is on the label
attached to the terminal block as
shown in the following figure.
Main Block
The serial number is printed on
the main bock as shown in the
following figure.
DIP Switch
Used to set the input
type and display mode.
Terminal
Block
LED Indicators
Display Unit status.
Test Pins
Terminal Insertion Holes
Release Buttons
Cold junction compensator
Do not touch or remove.
(GRT1-TS2T only)
Name Color Status Meaning
ERR0 Red Lit Error An input error has occurred in
input 0.
An error has occurred in the cold
junction compensator
(GRT1-TS2T only).
--- Not lit Normal status There is no input error for input 0.