327
Explicit Messages Appendix A
Note (1) The Instance ID specifies the Slice I/O Unit’s unit number (1 to 63 decimal).
(2) The data structure is as follows:
If you want to write “LL = 7FFF FFFF, UL = 8000 0000” use the following: FFFF FF7F 0000 0080.
Action on
Bus Idle
Write Writes the action
performed when
the bus enters
idle state.
0E hex 8E hex 01 to 40
hex
*1
98 hex 1 byte
00 hex: Outputs
are cleared on
bus idle.
01 hex: Output
functionality is
maintained on
bus idle.
---
Read Reads the action
performed when
the bus enters
idle state.
0E hex 8E hex 01 to 40
hex
*1
98 hex --- 1 byte
00 hex: Outputs
are cleared on bus
idle.
01 hex: Output
functionality is
maintained on bus
idle.
Explicit
message
Read/
write
Function Command Response
Service
code
Class
ID
Instance
ID
Attribute
ID
Data size