EasyManua.ls Logo

Omron Sti F3SJ-B N25-01T Series - External Dimensions to Attach the Top;Bottom Brackets (F39-LJB1) and Intermediate Brackets (F39-LJB2)

Omron Sti F3SJ-B N25-01T Series
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
F3SJ-B-01T
Quick Installation Manual
6-4. External dimensions to attach the top/bottom brackets (F39-LJB1) and intermediate brackets (F39-LJB2)
Dimensions (Check position)
M3 x 6 screw
M3 x 6 screw
P (beam gap)
13.4
22.5
34.5
B
A
5.5
30
19
6.5
dia.9
7.5
18.3
7
22
30
30
D
53
42
C (Protective height)
30
13
2
43
6.5
45
<M5 screw fixed> <M8 screw fixed>
Top/Bottom Bracket
(F39-LJB1)
Top/Bottom Bracket
(F39-LJB1)
Intermediate Bracket
(F39-LJB2)
2
E
19
B
B
E
C
C
E
42
42
5.9 5.9
22 22
4-M5
2-M8
2-M5 2-M5
[ Unit : mm ]
[Backside mounting]
If the protective height exceeds 1105mm, use the intermediate brackets as many as and on the positions specified in the
dimensional drawing. Otherwise ratings/specifications cannot be satisfied.
If load is applied to the sensor unit in your environment, add intermediate bracket(s).
Dimensions A to E and P
Dimensions E
* Value E must be 700 mm or less when not using value E obtained from the calculation above.
AC+69
BC+42.2
C 4-digit number of the type name (protective height)
DC-45
E Depends on the protective height. See the table below.
P20
Protective height Number of Intermediate Brackets Dimensions E
0185 to 1105 0 -
1185 to 1345 1 C/2 max.
1425 to 2065 2 C/3 max.
Check
position
Step1
Mount
Step2
Align
beams
Step3
Mounting/Beam Alignment
Wiring
Function Selection
Pre-Operation Checklist /
Maintenance Checklists

Related product manuals