563
ES100
@
Digital Controller Protocol Appendix K
Receive Data Word Allocation (4th Operand of PMCR(260))
Read Time Signal (Sequence No. 251 (Hex 00FB))
Reads time signals from 1 to 10 in the variable area.
Send Data Word Allocation (3rd Operand of PMCR(260))
Event 1
Event 9
Event 2
Receive data
storage words
Number of receive data words+0
+1
+2
+3
+4
+5
+121
+122
+123
+124
+125
Event 1
~ ~
1st unit
25th unit (max.)
Event 2
Event 3 Event 4
Event 5 Event 6
Event 7 Event 8
Event 10
Event 3 Event 4
Event 5 Event 6
Event 7 Event 8
Event 9 Event 10
Offset Contents (data format) Data
+0 Number of receive data words
(4 digits Hex)
Number of units x 5 + 1
+1 1st unit
Event data 1 (2 digits Hex)
Event data 2 (2 digits Hex)
00 to FF
00 to FF
+2 1st unit
Event data 3 (2 digits Hex)
Event data 4 (2 digits Hex)
00 to FF
00 to FF
+3 1st unit
Event data 5 (2 digits Hex)
Event data 6 (2 digits Hex)
00 to FF
00 to FF
+4 1st unit
Event data 7 (2 digits Hex)
Event data 8 (2 digits Hex)
00 to FF
00 to FF
+5 1st unit
Event data 9 (2 digits Hex)
Event data 10 (2 digits Hex)
00 to FF
00 to FF
+125
(max.)
25th unit
Event data 9 (2 digits Hex)
Event data 10 (2 digits Hex)
00 to FF
00 to FF
Offset Contents (data format) Data
+0 Number of send data words
(4 digits Hex)
Number of units + 2
+1 Number of units (4 digits Hex) 0001 to 0019 (1 to 25 decimal)
+2 1st unit
Unit No. (2 digits BCD)
00 to 31
(Undefined)
Unit No.
First word of
send data
Number of send data words+0
+1
+2
+3
+26
(Undefined)
Unit No.
Number of units
(Undefined)
Unit No.
~ ~
25th unit (max.)
2nd unit
1st unit