What to do if Omron Controller cannot open the communications with current settings?
D
Danielle McintoshSep 6, 2025
If you cannot open communications with the current settings on the Omron Controller, the routing table setting may be incorrect. Reset the routing table of the Ladder Engine using the CX-Net so that it does not overlap with the network No. used by FinsGateway.
M
michaelbryantAug 25, 2025
What to do if Omron Controller CX-Simulator Ladder Engine failed to start?
T
Thomas PayneAug 25, 2025
If the Omron Controller CX-Simulator Ladder Engine fails to start, it could be due to a wrong execution environment. Try these steps:
1. Exit any running application programs, keeping only the CX-Simulator active.
2. Uninstall and then reinstall the CX-Simulator.
S
Stephanie DavisAug 25, 2025
Why does Omron Controller show an error while initializing Debugger startup?
S
Sandra BryantAug 26, 2025
If an error occurs while initializing the Debugger startup on the Omron Controller, it may be due to a wrong execution environment. To resolve this:
1. Exit any running application programs other than the CX-Simulator, and try starting the Debugger again.
2. If the issue persists, uninstall and then reinstall the CX-Simulator.
T
Tara PopeAug 27, 2025
What to do if Omron Controller failed to start I/O Condition Tool?
L
lamdeannaAug 27, 2025
If the Omron Controller I/O Condition Tool fails to start, it may be due to poor resources or a wrong execution environment. Try these steps:
1. Exit any running application programs except the CX-Simulator and try again.
2. Uninstall, then reinstall the CX-Simulator.
A
Angel GriffithAug 27, 2025
Why Omron Controller failed to save PLC data file?
M
Mary RobinsonAug 27, 2025
If the Omron Controller fails to save the PLC data file, it may be due to low hard disk space or lack of access rights. Verify that the hard disk has sufficient space and that the user has authorization to write files.
R
rebeccabatesAug 28, 2025
What causes Omron Controller to fail to gain access rights of CX-Simulator Ladder Engine?
C
Christopher HolmesAug 28, 2025
If the Omron Controller CX-Simulator Ladder Engine fails to gain access rights, it could be because another application program is writing to the UM. Wait until the writing application program is completed, and then try again.
J
Joseph MccoySep 12, 2025
How to fix Omron Controller failed to start the Alarms display application?
T
Tara RichardsSep 12, 2025
If the Omron Controller fails to start the Alarms display application, it is due to the wrong environment for the Alarms display application. The event viewer is not working for Windows NT and the memo pad for Windows95/98. Change the OS settings so as to work.
J
Jason LeeSep 13, 2025
Why Omron Controller failed to create a folder for the card files?
H
Heather White MDSep 13, 2025
If the Omron Controller fails to create a folder for the card files, it could be because the PLC data folder is read-only. Delete the PLC data folder and all files/folders in it, and then create a new PLC again.
M
Megan BaxterSep 5, 2025
How to fix Omron Controller failed to create command log file?
A
Amy ScottSep 5, 2025
If the Omron Controller fails to create a command log file, it may be because the specified file is read-only or the disk space is low. Increase the disk space or change the destination for creating the log file.
M
Mark SextonSep 2, 2025
What causes Omron Controller to fail to read the PLC data file?
K
Kimberly MullinsSep 2, 2025
If the Omron Controller fails to read the PLC data file, it could be because the set file is broken. Reset the set file in the setting wizard to resolve this.
Omron CS Series Specifications
General
Manufacturer
Omron
Category
Network Hardware
Mounting
DIN Rail
Type
PLC
Series
CS Series
Programming Language
Ladder Diagram, Instruction List, Function Block Diagram, Structured Text, Sequential Function Chart
Communication Ports
Ethernet
Protocols Supported
Modbus, Ethernet/IP
Power Supply
24V DC or 100-240V AC
Operating Temperature
0°C to 55°C
Storage Temperature
-25°C to 65°C
Humidity Range
10% to 90% (non-condensing)
Vibration Resistance
10 to 57 Hz, 0.075 mm amplitude; 57 to 150 Hz, 1 G
Shock Resistance
150 m/s² (15 G) in X, Y, and Z directions 3 times each