EasyManua.ls Logo

Omron V700-HMD13 series - Page 60

Omron V700-HMD13 series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
58
Section 4
4.4 Message specifications
V700-L21
User's Manual
Section 4
SECS Protocol Specifications
S18,F13 Subsystem command request (PerformDiagnostics) S,HE,reply
L,3
1.<TARGETID> "00"-"31"
2.<SSCMD> "Perform Diagnostics"
3.L,0
S18,F14 Subsystem command acknowledge (PerformDiagnostics) S,HE
L,3
1.<TARGETID> "00"-"31"
2.<SSACK>
3.L,s
1.<STATUS1>
.
s.<STATUSs>
• When the specified target is invalid:
s=0, SSACK = CE (communications error)
• When SSCMD is invalid:
s=0, SSACK = CE (communications error)
• When SSACK is other than NO (normal), the List of Status will take a list structure with which the number of items is 0.

Table of Contents