Once your regulator is connected, open up the gas from your
propane tank.
Push in and slowly turn the control knob counter-clockwise
until you hear a click and the burner ignites.
Continue to push in the control knob for 5 seconds after
ignition and then release.
Ooni Koda should run quietly when lit. If you hear a roaring
noise from the gas burner, switch the gas o for 5 minutes and
re-light.
What to do if the flames go out?
Our priority is for you to enjoy Ooni Koda in a safe and fun
environment and Ooni Koda has a Flame Safe Device (FSD)
built in. For safety reasons, if the flame is extinguished while
the gas supply is on, the FSD will automatically cut o the gas
supply in to Ooni Koda safely.
If you notice that the flames have gone out, turn o the gas
supply and detach Ooni Koda from the propane tank.
Leave for 5 minutes before re-lighting.
Lighting
O
Push, slowly turn and
hold for 5 seconds to light
Max. power
Min. power
Caution: Ooni Koda should run quietly when lit. If you hear a roaring noise
from the gas burner, switch the gas o for 5 minutes and re-light.
10 11