EasyManua.ls Logo

Optoma EW330 - Other

Optoma EW330
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EX330/EW330/EX330(1W)/EW330(1W) Condential
4-10
x 100%
- Follow Contrast formula to calculate contrast
values.
☼ Contrast Formula
P5/B5
note: P5=center of white image
B5=center of black image.
Criteria
- 1000:1(for EX330/EX330(1W))
- 550:1 (for EW330/EW330(1W))
4. Uniformity
Procedure - Full white pattern
- Use CL100 to measure brightness values of
P1~P9 (see image: full white).
- Follow the Uniformity formula to calculate
average values.
☼ Uniformity Formula
ANSI Uniformity = Avg. (P1, P3, P7, P9)
P5
Criteria - 65%
4-9 Others
1. Functional Inspection
Keypad button - All keypad buttons must operate
smoothly.
General - All OSD functions must be
checked for functionality. When
OSD menu is displayed, there
shall be no visible peaking,
ringing, streaking, or smearing
artifacts on the screen.