optris PI – E2010-03-A
13
Process Interface
The PI is equipped with a process interface, which can be programmed via the software as Analog Input [PIF
in] and Digital Input [PIF Digital Input] (to control the camera) or as Analog Output [PIF out] (to control the
process).
PIF in PIF out
Emissivity Main area temperature
Ambient temperature Internal temperature
Reference temperature Flag status
Flag control Alarm
Triggered recording
Triggered snapshots
The signal level is always 0-10 V.
Pin configuration Process Interface (PIF)
(outside view)
1 DIGITAL IN
2 10 V OUT
3 GND
4 OUT
5 IN
[ PI Interface]
PIF (Digital input)
Flag control
Triggered recording
Triggered snapshots