EasyManua.ls Logo

optris PI - Measurement Specifications

optris PI
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
optris PI – E2010-03-A
7
Measurement Specifications
Temperature ranges -20...100 °C
0...250 °C
120...900 °C
Spectral range 7,5...13 µm
Lenses 31° x 23°/ 9° x 7°
System accuracy
1)
±2 °C or ±2 %
Temperature resolution (NETD) 0,08 K
Frame rate 100 Hz
Warm-up time 10 min
Emissivity 0,100…1,000 (adjustable via software)
Measurement functions Measure points (1x1, 3x3 or 5x5 pixels); free adjustable location
Measurement rectangle; Size scalable; free adjustable location
Both of these functions can be combined with the signal processing
features: Average, MAX, MIN value.
Software PIConnect
1)
at ambient temperature 23±5 °C; whichever is greater