Mechanical Installation 35-
3.2.2 Water cooling
The IR camera is for application at ambient temperatures up to 50 °C. For applications at higher ambient
temperatures we recommend the usage of the optional water cooled housing (operating temperature up to
250 °C) and the optional high temperature cable (operating temperature up to 250 °C).
When using water cooling, a corresponding mounting kit (Part-No.: ACXIxxxWAKx) is
required (WAK1: Usage without air purge, WAK2: Usage with air purge).
Water flow rate: approx. 1-5 l/ min (Cooling water temperature should not exceed 30 °C)
When using the water cooling the air purge (Part-No.: ACXIAPL) is recommended in order
to avoid condensation
Material: Stainless steel
Weight: 1480 g