EasyManua.ls Logo

Oracle Database B10772-01 - Page 217

Default Icon
518 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring Your System to Use Hardware Security Modules
Conguring Secure Sockets Layer Authentication 7-51
Error Messages Associated with Using Hardware Security Modules
The following errors are associated with using PKCS #11 hardware security
modules:
ORA-43000: PKCS11: library not found
Cause: The system cannot locate the PKCS #11 library at the location specified
when the wallet was created. This happens only when the library is moved after
the wallet is created.
Action: Copy the PKCS #11 library back to its original location (where it was
when the wallet was created).
ORA-43001: PKCS11: token not found
Cause: The smart card that was used to create the wallet is not present in the
hardware security module slot.
Action: Ensure that the smart card that was used when the wallet was created
is present in the hardware security module slot.
ORA-43002: PKCS11: passphrase is wrong
Cause: This can occur when
An incorrect password is specified at wallet creation, or
The PKCS #11 device password is changed after the wallet is created
and not updated in the wallet by using Oracle Wallet Manager.
Action: Depending on the cause, take one of the following actions:
If you see this error during wallet creation, then check to ensure that
you have the correct password and re-enter it.
If the password changed after wallet creation, then use Oracle Wallet
Manager to open the wallet and enter a new password.
See Also: "Creating a Wallet to Store Hardware Security Module
Credentials" on page 8-11