Connecting
23
Connection example for I/O signals and programmable controller
z
Sink logic
24 VDC
CN5
4.5 to 30 VDC
100 mA or less→
IN-COM0
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN-COM1
OUT0+
OUT0
-
OUT1+
OUT1
-
100 mA or less→
0 V
2
1
3
4
5
6
7
6.6 kΩ
6.6 kΩ
6.6 kΩ
6.6 kΩ
6.6 kΩ
6.6 kΩ
1 kΩ
1 kΩ
1 kΩ
1 kΩ
1 kΩ
1 kΩ
8
6.6 kΩ
1 kΩ
15
R
∗
R
∗
17
16
18
Programmable controller Driver
9
0 V
Do not connect anything.
Recommended resistance value when the current limiting resistor R is connected
In the case of 24 VDC: 680 Ω to 2.7 kΩ (2 W) In the case of 5 VDC: 150 Ω to 560 Ω (0.5 W)
z
Source logic
24 VDC
CN5
4.5 to 30 VDC
100 mA or less→
100 mA or less→
0 V
2
1
3
4
5
6
7
6.6 kΩ
6.6 kΩ
6.6 kΩ
6.6 kΩ
6.6 kΩ
6.6 kΩ
1 kΩ
1 kΩ
1 kΩ
1 kΩ
1 kΩ
1 kΩ
8
6.6 kΩ
1 kΩ
15
R
∗
R
∗
17
16
18
Programmable controller Driver
9
0 V
IN-COM0
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN-COM1
OUT0+
OUT0
-
OUT1+
OUT1
-
Do not connect anything.
∗
Recommended resistance value when the current limiting resistor R is connected
In the case of 24 VDC: 680 Ω to 2.7 kΩ (2 W) In the case of 5 VDC: 150 Ω to 560 Ω (0.5 W)
Note
•
Use output signals at 4.5 VDC to 30 VDC.
•
Be sure to use the current of the OUT0 and OUT1 at 100 mA or less. If the current exceeds this value, connect the
current limiting resistor R.
•
Pass the current of 5 mA or more for the SPEED-OUT output.
•
Do not connect anything to the pin No. 9 when using an external power supply.