EasyManua.ls Logo

Orion AD-5 - How to Identify the Cause of a Problem; Bowl Not Draining; Continuous Discharging; Air Leaking

Orion AD-5
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Troubleshooting
How to identify the cause of a problem
How to identify the cause of a problem
If the bowl is not drained of water:
If the Auto Drain Trap keeps discharging without a break:
If air is leaking:
Is the disc
operating ?
Disc is clogged.
YES
No
Screen is clogged.
Wash the inside of the
Bowl and ca
p
.
Wash the inside of the
Bowl and cap.
Valve hole is clogged.
Wash the valve hole and
give air blow.
Filter is clogged.
Wash the filter and
give air blow.
Washer and packing
Are worn or dama
g
ed.
YES
No
Replace the main body.
Replace the washe
r
And packing.
Disc is worn or damaged.
Replace the disc.
Needle valve is worn or
damaged.
Replace the needle valve.
Disc is not operating
correctly.
Wash the inside of the bowl
and cap.
Washer, packing, cap, and/or
O-ring are worn or degraded.
Replace the washer,
packing,
Main body is worn
or dama
g
ed.
Is the disc
operating ?

Related product manuals