14
Street elbow
Ball valve
Close
Silencer
Nipple
Drain plug
Muffler
Silencer
Nipple
How to install an optional part
Installing a muffler assembly (part No. 03006716010)
1.
Remove any water from the Auto Drain Trap.
(1)
Close the ball valve.
(2)
Loosen the drain plug.
2.
Remove the street elbow.
(1)
Remove the silencer and nipple from the street
elbow.
3.
Attach the muffler.
(1)
Connect the muffler's IN port to the outlet of the
main body.
(2)
Connect the silencer and nipple to the muffler's
OUT port.
*Completely installed muffler assembly is shown to
the right.
Storage (if you are not using this product for a long)
1. Drain the Auto Drain Trap.
Remove any water from the Auto Drain Trap.
Turn the drain plug--which is located at the bottom of the Auto Drain Trap--in a clockwise
direction to remove the water accumulated in the bowl.
If you fail to remove the water, the internal parts of the Auto Drain Trap may become
damaged due to corrosion and it could fail as a result.
2.
Disassemble and clean the Auto Drain Trap.
Follow the procedures described in the "Daily inspection and maintenance" section, page 7,
to clean the Auto Drain Trap.
3.
Store the Auto Drain Trap in an appropriate place.
Make sure that it is not exposed to foreign matter, dust, rainwater, moisture, etc.
Disposal
Please collect a refrigerant before disposing of this plane. The basis comes in a law / the
regulations of the country (an area) to use, and please handle the disposal of refrigerant
which I collected adequately.