-66- -67-
-
Send To LCD
 
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 0x10 0x01 0x04 Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0) , Write(Set) – 0x02(2)
*Control : Power O – 0x00(0) , Power On – 0x01(1)
-
Receive From LCD
 
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x10 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get)Response – 0x00(0), Write(Set)Response – 0x02(2)
*Control : Power O – 0x00(0) , Power On – 0x01(1)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
3.3. Input Source
-
This is the command for changing the input source.
-
This command is available while power is on.
-
CMD : 0xD1
-
Send To LCD
 
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Input Source
Value 0x02 0xD1 0x01 0x04 Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0), Write(Set) – 0x02(2)
* Input Source : 0x11(HDMI1A), 0x12(HDMI1B), 0x13(HDMI1C), 0x14(HDMI1D), 0x15(HDMI2A), 0x16(HDMI2B), 0x17(HDMI2C),
0x18(HDMI2D),0x31(UHD 1), 0x32(UHD 2)
-
Receive From LCD
 
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0xD1 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get)Response – 0x00(0), Write(Set)Response – 0x02(2)
* Input Source : 0x11(HDMI1A), 0x12(HDMI1B), 0x13(HDMI1C), 0x14(HDMI1D), 0x15(HDMI2A), 0x16(HDMI2B), 0x17(HDMI2C),
0x18(HDMI2D),0x31(UHD 1), 0x32(UHD 2)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
3.4. Information
-
It is the command for displaying the information of LCD set status.
-
It is available only during Power On (Operative) status.
-
CMD : 0x1A
-
Send To LCD
 
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode
Value 0x02 0x1A 0x01 0x03 Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Write(Set) – 0x02
-
Receive From LCD
 
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode
Value 0x02 0x1A 0x01 0x03 Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Write(Set)Response – 0x02(2)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
4. Picture Control Command
4.1. Brightness Control
-
This is the command to adjust the overall image and background brightness.
-
It is available only on Power On (Operative) status.
-
The adjusted value cannot be applied for Stand-By or No input status. So, it can be applied when LCD is in operating condition with the input
signal.
-
CMD : 0x20
-
Send To LCD
 
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 0x20 0x01 0x04 Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0) , Write(Set) – 0x02(2)
*Control : 0x00(0) ~ 0x64(100)
-
Receive From LCD
 
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x20 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get)Response – 0x00(0), Write(Set)Response – 0x02(2)
*Control : 0x00(0)~0x64(100)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
4.2. Contrast Control
-
This is the command to adjust the image brightness in relationship to the background.
-
It is available only on Power On (Operative) status.
-
The adjusted value cannot be applied for Stand-By or No input status. So, it can be applied when LCD is in operating condition with the input
signal.
-
CMD : 0x21
-
Send To LCD
 
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 0x21 0x01 0x04 Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0) , Write(Set) – 0x02(2)
* Control : 0x00(0) ~ 0x64(100)