-68- -69-
-
Receive From LCD
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x21 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get)Response – 0x00(0), Write(Set)Response – 0x02(2)
*Control : 0x00(0) ~ 0x64(100)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
4.3. Color Control
-
This is the command to adjust the color depth of the screen.
-
It is available only on Power On (Operative) status.
-
CMD : 0x25
-
Send To LCD
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 0x25 0x01 0x04 Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0) , Write(Set) – 0x02(2)
*Control : 0x00(0) ~ 0x64(100)
-
Receive From LCD
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x25 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get)Response – 0x00(0), Write(Set)Response – 0x02(2)
*Control : 0x00(0) ~ 0x64(100)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
4.4. Tint Control
-
This is the command to adjust the tint of the screen.
-
It is available only on Power On (Operative) status.
-
The adjusted value cannot be applied for Stand-By or No input status. So, it can be applied when LCD is in operating condition with the input
signal.
-
CMD : 0x24
-
Send To LCD
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 0x24 0x01 0x04 Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0) , Write(Set) – 0x02(2)
*Control : 0x00(0) ~ 0x64(100)
-
Receive From LCD
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x24 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get)Response – 0x00(0), Write(Set)Response – 0x02(2)
*Control : 0x00(0) ~ 0x64(100)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
4.5. Video Mode(Color Temperature Mode)
-
This is command to adjust the color temperature of the entire screen. A WARM(6500K) will make the screen reddish.
A COOL(1000K) will make the screen bluish. A Natural is the color temperature of the typical panel without any adjustmen. A Polycom is the
requested color temperature of buyer. If COLOR TEMPERATURE needs further adjustment, CUSTOM must be showing as the Video Mode
selection.
-
Color temperature is 8000K for Polycom mode, 10000K for Cool mode and 6500K for Warm mode. Natural Mode is the color temperature of the
typical panel without any adjustment. User can control the color temperature with Custom mode.
-
It is available only on Power On (Operative) status.
-
The adjusted value cannot be applied for Stand-By or No input status. So, it can be applied when LCD is in operating condition with the input
signal.
-
CMD : 0x26
-
Send To LCD
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 0x26 0x01 0x04 Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0) , Write(Set) – 0x02(2)
*Control : Polycom(0x01), Cool(0x02), Normal(0x03), Warm(0x04), Custom(0x05)
-
Receive From LCD
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x26 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get)Response – 0x00(0), Write(Set)Response – 0x02(2)
*Control : TBD
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
5. Screen Adjustment Command
5.1. H Position
-
This is the command to control the horizontal position of the image within the Display area of the LCD.
-
CMD : 0x36
-
Send To LCD
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 0x36 0x01 0x04 Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0), Write(Set) – 0x02(2)
*Control Value : 0x00(0)~0x64(100)
-
Receive From LCD
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x36 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get)Response – 0x00(0), Write(Set)Response – 0x02(2)