-74- -75-
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Write(Set) – 0x02(2)
* Control Value: The ranges of each 1Byte of IP Address, Subnet Mask, Default Gateway, DNS Primary, or DNS Secondary are from 0(0x00) to
255(0xFF)
-
Receive From LCD
 
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x74 0x01 0x17 Variable Variable Variable Variable Variable 0x03
IP Address
(4Byte)
Subnet Mask
(4Byte)
Default Gateway
(4Byte)
DNS Primary
(4Byte)
DNS Secondary
(4Byte)
Value
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Write(Set)Response – 0x02(2)
*Control : The ranges of each 1Byte of IP Address, Subnet Mask, Default Gateway, DNS Primary, or DNS Secondary are from 0(0x00) to 255(0xFF)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
6.6. Get LCD Network IP
-
This is the command for checking the conguration for LCD Network IP such as DHCP settings, IP Address, Subnet Mask, Default Gateway, DNS
Primary, and DNS Secondary.
-
CMD : 0x75
-
Send To LCD
 
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode
Value 0x02 0x75 0x01 0x03 Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0)
-
Receive From LCD
 
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x75 0x01 0x18 Variable Variable Variable Variable Variable 0x03
DHCP ON,OFF
(1Byte)
IP Address
(4Byte)
Subnet Mask
(4Byte)
Default Gateway
(4Byte)
DNS Primary
(4Byte)
DNS Secondary
(4Byte)
Value
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0)
*Control: If DHCP conguration is deselected, it is 0(0x00). If it is selected, it is 1(0x01). The length of IP Address, Subnet Mask, Default Gateway,
DNS Primary, and DNS Secondary is 4Bytes, respectively.
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
6.7. Get MAC Address
-
This is the command for checking MAC Address.
-
CMD : 0x76
-
Send To LCD
 
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode
Value 0x02 0x76 0x01 0x03 Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0)
-
Receive From LCD
 
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x76 0x01 0x09 Variable Variable Variable Variable Variable 0x03
Mac Address
(1Byte)
Mac Address
(1Byte)
Mac Address
(1Byte)
Mac Address
(1Byte)
Mac Address
(1Byte)
Mac Address
(1Byte)
Value Variable Variable Variable Variable Variable Variable
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0)
*Control Value: The range of each value is from 0(0x00) to 255(0xFF).
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
6.8. Baud Rate
-
This is the command for conguring the Baud Rate for LCD communication.
-
It is available only during Power On (Operative) status.
-
CMD : 0x78
-
Send To LCD
 
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 0x78 0x01 0x04 Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Write(Set) – 0x02(2)
*Control : 96001(0x01), 144002(0x02), 192003(0x03), 384004(0x04), 576005(0x05), 115200 - 6(0x06)
-
Receive From LCD
 
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x78 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Write(Set)Response – 0x02(2)
*Control : 96001(0x01), 144002(0x02), 192003(0x03), 384004(0x04), 576005(0x05), 115200 - 6(0x06)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
6.9. Get Baud Rate Data
-
This is the command for checking the conguration of the Baud Rate for LCD communication.
-
It is available only during Power On (Operative) status.
-
CMD : 0x79
-
Send To LCD
 
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode
Value 0x02 0x79 0x01 0x03 Variable Variable Variable 0x03