-76- -77-
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0)
-
Receive From LCD
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x79 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0)
*Control : 9600 – 1(0x01), 14400 – 2(0x02), 19200 – 3(0x03), 38400 – 4(0x04), 57600 – 5(0x05), 115200 - 6(0x06)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
6.10. OSD Turn O
-
This is the command for conguring the duration time for OSD Menu.
-
It is available only during Power On (Operative) status.
-
CMD : 0x7D
-
Send To LCD
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 0x7D 0x01 0x04 Variable Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Write(Set) – 0x02(2)
*Control: The value for Turn OFF is 0(0x00), 10 seconds is 1(0x01), 20 seconds is 2(0x02), and 30 seconds is 3(0x03).
-
Receive From LCD
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x7D 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Write(Set)Response – 0x02(2)
*Control: The value for Turn OFF is 0(0x00), 10 seconds is 1(0x01), 20 seconds is 2(0x02), and 30 seconds is 3(0x03).
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
6.11. OSD Info Display Time
-
This is the command for selecting Info OSD display on the screen and conguring the duration.
-
It is available only during Power On (Operative) status.
-
CMD : 0x80
-
Send To LCD
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 0x80 0x01 0x04 Variable Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0), Write(Set) – 0x02(2)
*Control Value: The value for OFF is 0(0x00) and the duration can be selected between 3(0x03) and 10(0x0A).
-
Receive From LCD
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x80 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get)Response – 0x00(0), Write(Set)Response – 0x02(2)
*Control Value: The value for OFF is 0(0x00) and the duration can be selected between 3(0x03) and 10(0x0A).
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
6.12. Get OSD Control Data
-
This is the command for checking the OSD related conguration such as OSD Turn O Time, or OSD Info Display duration.
-
It is available only during Power On (Operative) status.
-
CMD : 0x82
-
Send To LCD
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode
Value 0x02 0x82 0x01 0x03 Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0)
-
Receive From LCD
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x82 0x01 0x05 Variable Variable Variable Variable Variable 0x03
OSD Turn O Time
(1Byte)
OSD Info Display Time
(1Byte)
Value Variable Variable
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get)Response – 0x00(0)
*Control Value : The value for Turn OFF is 0(0x00), 10 seconds is 1(0x01), 20 seconds is 2(0x02), and 30 seconds is 3(0x03).
The duration rages for OSD Info Display Time can be selected between 3(0x03) and 10(0x0A) and OFF is 0(0x00).
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
7. SETUP B Command
7.1. Power On Source
-
This is the command for selecting and conguring the input source that should be detected with the rst priority at the time of Power On.
-
It is available only during Power On (Operative) status.
-
CMD : 0x63
-
Send To LCD
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 0x63 0x01 0x04 Variable Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Write(Set) – 0x02(2)
*Control : Input Source conguration
0x10 is for the last input source at the time of the last Power O. 0x11(HDMI1A), 0x12(HDMI1B), 0x13(HDMI1C), 14(HDMI1D),
0x15(HDMI2A), 0x16(HDMI2B), 0x17(HDMI2C), 0x18(HDMI2D), 0x31(UHD 1), 0x32(UHD 2).
-
Receive From LCD
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x63 0x01 0x04 Variable Variable Variable Variable Variable 0x03