-78- -79-
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Write(Set)Response – 0x02(2)
*Control : Input Source conguration
0x10 is for the last input source at the time of the last Power O. 0x11(HDMI1A), 0x12(HDMI1B), 0x13(HDMI1C), 14(HDMI1D),
0x15(HDMI2A), 0x16(HDMI2B), 0x17(HDMI2C), 0x18(HDMI2D), 0x31(UHD 1), 0x32(UHD 2).
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
7.2. Get Power On Source Data
-
This is the command for checking the conguration of the input source that should be detected with the rst priority at the time of Power On.
-
It is available only during Power On (Operative) status.
-
CMD : 0x66
-
Send To LCD
 
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode
Value 0x02 0x66 0x01 0x03 Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0)
-
Receive From LCD
 
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x66 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get)Response – 0x00(0)
*Control : Input Source conguration
0x10 is for the last input source at the time of the last Power O. 0x11(HDMI1A), 0x12(HDMI1B), 0x13(HDMI1C), 0x14(HDMI1D),
0x15(HDMI2A), 0x16(HDMI2B), 0x17(HDMI2C), 0x18(HDMI2D), 0x31(UHD 1), 0x32(UHD 2).
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
7.3. KEY LOCK
-
It prevents the unexpected change for panel or set conguration.
-
CMD : 0xB0
-
Send To LCD
 
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 0xB0 0x01 0x04 Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0) , Write(Set) – 0x02(2)
*Control : Panel Key Lock O – 0x00(0) , Panel Key Lock On – 0x01(1)
-
Receive From LCD
 
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0xB0 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group ID/Multi ID range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get)Response – 0x00(0), Write(Set)Response – 0x02(2)
*Control : Panel Key Lock O – 0x00(0) , Panel Key Lock On – 0x01(1)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
8. Factory Control Command
8.1. Dimming Control
-
This is the command for controlling the brightness of LCD back light.
-
It is available only during Power On (Operative) status.
-
CMD : 0x1D
-
Send To LCD
 
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 0x1D 0x01 0x04 Variable Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get) – 0x00(0), Write(Set) – 0x02(2)
*Control Value: The range of Control value is from 0x00(0) to 0xFF(255).
-
Receive From LCD
 
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 0x1D 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Read(Get)Response – 0x00(0), Write(Set)Response – 0x02(2)
*Control Value: The range of Control value is from 0x00(0) to 0xFF (255).
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
8.2. White Balance Control
-
This is the command for adjusting the values for Gain RGB or Oset RGB of White Balance.
-
Since the adjusted values cannot be applied while Stand-by status or without input signal, LCD must be in operating condition with input signal.
-
CMD : 0x27(Gain Red), 0x28(Gain Green), 0x29(Gain Blue), 0x2A(Oset Red), 0x2B(Oset Green), 0x2C(Oset Blue)
-
Send To LCD
 
STX CMD Ex CMD Length
Data
ETX
Group ID Multi ID Mode Control
Value 0x02 Variable 0x01 0x04 Variable Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Write(Set) – 0x02
*Control: The controllable range of Gain RGB and Oset RGB is from 0(0x00) to 200(0xC8), respectively.
-
Receive From LCD
 
STX CMD Ex CMD Length
Data
Check Sum ETX
Group ID Multi ID Mode Control
Value 0x02 Variable 0x01 0x04 Variable Variable Variable Variable Variable 0x03
*Group/Multi ID Range(Program) : Group ID : 0x01 / Multi ID : 0x01 Fixed
*Mode : Write(Set)Response – 0x02(2)
*Control: The controllable range of Gain RGB and Oset RGB is from 0(0x00) to 200(0xC8), respectively.
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.