UPS ORVALDI
V1000-3000 on line 2U LCD
Uninterruptible Power Supply System
User Manual

Questions and Answers

Summary

Important Safety Warning

1-1. Transportation

Guidelines for safely transporting the UPS system.

1-2. Preparation

Instructions for preparing the UPS system before installation.

1-3. Installation

Precautions and guidelines for installing the UPS system.

1-4. Operation

Key operational guidelines and safety precautions.

1-5. Maintenance, service and faults

Information on maintenance, service procedures, and fault handling.

Installation and setup

2-1. Rear panel view

Diagrams and explanations of the UPS rear panel connectors and ports.

2-2. Rack-Mounted the UPS

Steps for mounting the UPS unit in a 19-inch rack chassis.

2-3. Setup the UPS

Procedure for connecting battery wires, input power, and output connections.

2-4 Battery replacement

Procedure for replacing the UPS internal batteries without shutting down.

2-5 Battery kit assembly (option)

Instructions for assembling optional battery kits.

Operations

3-1. Button operation

Explanation of the functions of each button on the UPS panel.

3-2. LCD Panel

Overview of the UPS LCD panel display elements and indicators.

3-3. Audible Alarm

Details on the audible alarm sounds and their meanings.

3-4. LCD display wordings index

Index of abbreviations and their meanings displayed on the LCD.

3-5. UPS Setting

Guide to configuring UPS parameters and settings.

3-6. Operating Mode Description

Description of different UPS operating modes like Online, ECO, and Bypass.

3-7. Faults Reference Code

Reference table for fault codes, icons, and events.

3-8. Warning indicator

Guide to warning indicators, icons, and associated alarms.

Troubleshooting

Storage and Maintenance

Maintenance Operation

Information on UPS operation, battery lifespan, and replacement.

Storage Guidelines

Recommendations for storing the UPS unit and recharging the battery.

Specifications

Orvaldi V3000 Specifications

General IconGeneral
Apparent Power3000 VA
Real Power2700 W
TopologyLine Interactive
Output Voltage230 V
Output Frequency50/60 Hz
Input Frequency50/60 Hz
Form FactorTower
Operating Temperature0-40°C
Storage Temperature-15-45°C
Battery TypeSealed Lead Acid
Communication PortsUSB, RS232
Battery Recharge Time4-6 hours
Humidity0-95 % RH @ 0-40°C (Non-condensing)