INSTALLATION
NOTE!Duringinspectionandmaintenance,servicingandtheremovaloftrappedwaste
etc:
1.Settomanualmode(MAN)onthecontrolpanel.
2. Disconnectthepowertothemachinebyremovingtheplugfromthewallsocket.
3. Do not work inside the machine.
WEEKLY INSPECTION AND MAINTENANCE
SAFETY CHECKS
- Check the shutter switch:itmustnotbepossibletostartthemachineiftheuppershutterisopen/opened.
- Check that the emergency stop is working.
- Check that all covers and guards are intact.
- Check that there are no oil leaks on the machine.
-Checkthattheelectricalsupplycableisintactandproperlyprotectedagainstimpact.
Ifanyfaultsarediscoveredinthefunctionslistedabove,themachinemustnotbeuseduntilithasbeen
repairedbyauthorisedservicepersonnel.
Servicin and repairs must only be carried out by qualied and competent personnel, and in accordance with the
machine manufacturer’s instructions.
Theservicelightwillcomeonwhenthemachinerequiresservicing.Contactauthorisedservicepersonnel.
When changing the oil: Contact the local authorities for guidance regarding the environmentally correct dis-
posal of waste oil. Miscibilitymustbetakenintoaccountwhenchangingand/ortoppinguptheoil.Themachine
comeslledwithmineraloilfromthefactory.
TROUBLESHOOTING:
First, check:
OVERLOAD PROTECTION
NORMAL TRIPPED
FUSE