20
English
Adjusts: Parameter setting:
(for service
technicians)
To set:
use the
buttons:
Seconds
to hold
down the
buttons.
Flashing acknowledgement
(appears on the LED panel
immediately after mode is
selected)
The machine’s basic
mode (only the basic
functions are activated).
TiHatchClose=5
Frequency-based
HatchParkFreqEnabled
=off
CompParkFreqEnabled
=off
3
x6
The number of motion
sensor detections before
compaction.
MaxSessBefComp
3
+
freely
selected
number
x selected number
The number of seconds
the feed hatch stays open
per opening.
TiHatchClose
3
+
freely
selected
number of
seconds
(between 10
and 100) in
increments
of 10
x selected number
(in increments of 10)
The frequency-based
hatch opening setting is
set to its default value
(= 4 motion sensor detec-
tions/minute).
HatchParkFreqEnabled
= on
3
x3
The frequency-based
time interval for the
press plate in the com-
paction position setting
is set to its default value
(=30 minutes).
CompParkFreqEnabled
= on
3
x3
S1 S2 S3 S4
For positioning, see the section
PARTS OF THE MACHINE.
BUTTONS - for setting the operating modes
8