Heat pump Calidi XP
MA20-23 GB Translation of the original instructions (Swedish)
Defrosting
Automatic defrosting:
When the heat pump defrosts, the symbol “heating” ashes in the display.
Extra defrosting:
If defrosting is e󰀨ected automatically not su󰀩cient to do away with excessive ice on the
heat pump back side extra defrosting option can be enabled.
Before activating extra defrosting, make sure that the compressor has been in operation
for at least 10 minutes.
Enable extra defrosting by simultaneously pressing the buttons “eco” and ▼ for 5 seconds.
Maintenance
Service maintenance should be done once a year.
Check that no unusual noises are coming from the heat pump when it is in operation.
Regularly check the bolts, cables and connections.
Turn o󰀨 the heat pump during thunderstorms.
Clean the heat pump’s intake from any leaves, pine needles and other dirt that can obstruct circulation.
Clean the exterior heat pump with household detergents or clean water, NEVER use gasoline, thinners or similar liquids.
NOTE! Always turn o󰀨 the power supply to the pump before cleaning , inspection and repair.
Winter storage
Product warranty does not cover frozen heat exchangers.
For the winter season, or if the unit has not been used for a long time, the electricity should be
shut o󰀨 and the heat exchanger drained of all water.
Close the valves and drain the heat exchanger by loosening the lower pipe connection.
If associated bypass kit and/or plastic valves are used, they must be half opened to avoid frost
damage.
Cover the heat pump, when it is not running, with the supplied protection in order to protect it