Clearing the Service Counter (Maintenance Counter)
After 5000 cycles (lifts) the tail lift should be serviced. The con-
trol box will flash for 2 seconds with high frequency after switch-
on to indicate that this limit value is reached. Proceed as de-
scribed below to clear the service counter after this.
Close the platform, but leave the control box switched on.
Disconnect plug J 11.
Disconnect plug J 30.
Connect the service plug.
Connect plug J 11.
The service counter is cleared.
Disconnect the service plug.
Connect plug J 30.
Disconnect plug J 11 and connect it again.
This switches the tail lift back into operating mode.
Note: You can also reset the service counter by using the diag-
nostic software.
Troubleshooting
This function is only available for special program versions. For
more information please contact our customer service. Pro-
ceed as follows to troubleshoot the tail lift:
Switch on the control box.
Open the platform so that it is in horizontal position.
Disconnect plug J 11.
Disconnect plug J 30.
Connect the service plug.
Connect plug J 11.
Disconnect the service plug.
Connect plug J 30.
Every connected input is now indicated by continuous
warning lights.
If your tail lift is not equipped with Warnfix, you have to con-
nect a test lamp to PIN 7 of plug J3.
Disconnect plug J 11 and connect it again.
This switches the tail lift back into operating mode.
Note: You can also troubleshoot your tail lift by using the diag-
nostic software.