148
Changing the Hydraulic Oil
47 Oil drain plug
48 Hydraulic oil reservoir
49 Suction filter in the oil reservoir
50 Breather filter
51 Valve block
52 Clamp
V
CAUTION!
Risk of injury or material damage through waste oil!
If you do not change the oil in the hydraulic unit once a year,
condensation water could accumulate, especially at tempera-
tures below the freezing point. This disturbs the function of
the column lift. Persons could be injured and material could
be damaged.
Change the hydraulic oil once every year.
Preferably change the oil shortly before the start of the
winter season.
48
50
49
52
47
51
Betriebsanleitung_Hubladebuehnen_EN.book Seite 148 Donnerstag, 15. August 2019 4:04 16