130
Service functions (not available for all models)
Status Description Action for disabling
Error
No voltage across J1/2 -> check fuse
Automatic error reset as soon as
voltage is present across J1/2.
Error
Emergency program, sensor system
being bridged. Re-enable by pressing
and holding “Open“ and “Lower“ push-
buttons for more than 10 seconds.
Switch off/on control box
Error
Error diagnosis of all inputs is active.
Warnfix is activated upon each push-
button actuation.
Remove service plug
Error
“Selflock” function is active. Tail lift is
locked via radio receiver
(e. g. ICP).
Selflock = automatic locking of the con-
trol panel when the vehicle is left
Reset “Selflock” function:
Switch off/on control box or
place radio transmitter near the ra-
dio receiver again
Error
Interface not active due to short circuit
of “JP” connector (CAN).
De-energize board for some sec-
onds
Error
Error of special function (e. g. light bar-
rier of vertical lift program V-SYCL) is
defective.
Switch tail lift to emergency opera-
tion / replace light barrier
Bedienung_Tastencode_EN.fm Seite 130 Donnerstag, 15. August 2019 4:13 16