CAUTION
1. Do not install the Tank Unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of
the unit, it may cause fire.
2. Do not install the outdoor unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding
of the unit, it may cause fire.
3. Prevent liquid or vapor from entering sumps or sewers since vapor is heavier than air and may form suffocating atmospheres.
4. Do not release refrigerant during piping work for installation, re-installation and during repairing a refrigeration parts. Take care of the
liquid refrigerant, it may cause frostbite.
5. Do not install this appliance in a laundry room or other high humidity location. This condition will cause rust and damage to the unit.
6. Make sure the insulation of power supply cord does not contact hot part (i.e. refrigerant piping, water piping) to prevent from insulation
failure (melt).
7. Do not touch the sharp aluminium fin, sharp parts may cause injury.
8. Do not apply excessive force to water pipes that may damage the pipes. If water leakage occurs, it will cause flooding and damage to
other properties.
9. Do not transport the Tank Unit with water inside the unit. It may cause damage to the unit.
10. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage
the furniture.
11. Select an installation location which is easy for maintenance.
Incorrect installation, service or repair of this Tank Unit may increase the risk of rupture and this may result in loss damage or injury
and/or property.
12. Select an installation location which is easy for maintenance.
Incorrect installation, service or repair of this outdoor unit may increase the risk of rupture and this may result in loss damage or injury
and/or property.
13. Power supply connection to Tank Unit.
• Power supply point should be in easily accessible place for power disconnection in case of emergency.
• Must follow local national wiring standard, regulation and this installation instruction.
• Strongly recommended to make permanent connection to a circuit breaker.
- Power Supply 1: Use approved 30A 2-poles circuit breaker with a minimum contact gap of 3.0mm.
- Power Supply 2: Use approved 30A 2-poles circuit breaker with a minimum contact gap of 3.0mm.
14. Ensure the correct polarity is maintained throughout all wiring. Otherwise, it will cause electrical shock or fire.
15. After installation, check the water leakage condition in connection area during test run. If leakage occurs, it will cause damage to other
properties.
16. If the Tank Unit not operates for long time, the water inside the Tank Unit should be drained.
17. Installation work.
It may need three or more people to carry out the installation work. The weight of Tank Unit might cause injury if carried by one person.
18. Installation work.
It may need two or more people to carry out the installation work. The weight of outdoor unit might cause injury if carried by one
person.
19. Keep any required ventilation openings clear of obstruction.