EasyManuals Logo

Panasonic CS-A181KE User Manual

Panasonic CS-A181KE
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
– 14 –
MAC9512086C2
CS-A181KE
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during cooling operation.
Fan speed rotates in the range of Hi to Me.
Deodorizing Control.
Operation Details
Cooling Operation Time Diagram
* 1 Fan Speed is Hi until the compressor stops (when the room temperature reaches
setting temperature).
* 2 Fan Speed is Me after the compressor restarts.
<Description of operation>
d – g : Time Delay Safety Control (waiting for 3 minutes)
g – h : 60 sec. Forced Operation
h – o : 7 min. Time Saved Control
q – t : Anti Freezing Control
v – y : Outdoor Fan Control
Indoor
Fan
Comp.
SLo SLo SLo SLo
ON ONOFF
stop stop stop
30"
stop
30"160"
1
40"
40"
20"
.
.
.
.
2
.
.
.
.
a
b
c
def
g
hi
j
klmnopq
rs
tuvwxyz
Basic Time
Compressor
Indoor Fan
Outdoor Fan
Operation LED
4 Way Valve
2 Way Valve (A241K)
1’ 3’ 1’ 7’ 1’
4’
1.5˚C
ON
OFF
Comp.
Intake Air
Temperature
Comp.
Set Temp.
Indoor
Heat
Exchanger
Temp.
10°C
2°C
HiHi Hi Lo Lo Lo Hi
Outdoor Air
Temperature
31˚C
29˚C
Operation
Stop
Untitled-3 6/21/00, 10:33 AM14