Page #14 background image
– 13 –
MAC9512086C2
CS-A181KE
Operation Details
1) Cooling Mode Operation
Cooling in operation according to Remote Control setting.
When the compressor is stopped by Power Switch, Remote Control or there is a power failure, it restarts after 3
minutes when the Power Switch, Remote Control is turned ON or the power supply is resumed.
When the setting temperature is reached during cooling operation, the compressor stops and it will not start for 3
minutes.
The compressor will start automatically if it has stopped for 7 minutes even if the room temperature is below the
compressor ON temperature.
Time Delay Safety Control (3 minutes)
7 minutes Time Saved Control
Anti-Freezing Control
If the temperature of the indoor heat exchanger
falls continously below 2°C for 4 minutes, the
compressor turns off to protect the indoor heat
exchanger from freezing. The fan speed setting
remains the same.
Compressor recommences when the indoor heat
exchanger temperature rises to 10°C (Recovery).
* 3 minutes waiting of Time Delay Safety Control
is valid for Cooling Operation.
Recovery
4 min
Compressor OFF
Indoor Heat
Exchanger
Temperature
(°C)
2
10
Untitled-9 6/21/00, 10:18 AM13