– 40  –
MAC9512086C2
CS-A181KE
Technical Data
LL
LL
L Operation characteristics
CS-A241K / CU-A241K
• Piping Length Characteristic (Colling)
• Cooling Characteristic
    30       32      34      36      38      40       42      44       
      OUTDOOR ROOM TEMPERATURE (°C)
[Condition]  Room temperature: 27/19°C
                   Cooling operation: High fan
                   Piping length: 7.5 m
16
15
14
13
12
11
13.0
12.5
12.0
11.5
11.0 
0.42
0.41
0.40
0.39
0.38
7.0
6.5
6.0
5.5
5.0
220V
240V 
I:                                                 Q:
Current (A)                                Cooling Capacity (kW)                              
LP:                                                              O: Outlet
Gas Side Piping Pressure (MPa)                   
 
Air Temperature (°C)                
I
LP
Q
O
 PIPING LENGTH (m)
52515 2010
15.0
14.5
14.0
13.5
13.0
12.5
13.0
12.5
12.0
11.5
11.0
0.42
0.41
0.40
0.39
0.38
6.5
6.0
5.5
5.0
4.5
220V
240V 
I:                                                  Q:
Current (A)                                 Cooling Capacity  (kW)                                
LP:                                                              O: Outlet
Gas Side Piping Pressure (MPa)           
 
Air Temperature (°C)                 
[Condition]  Room temperature: 27/19°C
                   Outdoor air temperature: 35/24°C
                   Cooling operation: High fan
I
LP
Q
O
• Heating Characteristic •  Piping Length Characteristic (Heating)
-6       -4       -2        0        2        4        6        8          
 OUTDOOR  AIR TEMPERATURE (°C)
[Condition]  Room temperature: 20°C
                   Heating operation:High fan
                   Piping length: 7.5 m
16
15
14
13
12
11
46
44
42
40
38
36
2.2
2.0
1.8
1.6
1.4
8.0
7.5
7.0
6.5
6.0
5.5
5.0
220V
240V 
I:                                                       Q:
Current (A)                              -     Heating Capacity (kW)                          -
LP:                                                              O: Outlet
Gas Side Piping Pressure (MPa)           
 Air Temperature (°C)                
I
Q
O
LP
15.0
14.5
14.0
13.5
13.0
12.5
46
45
44
43
42
2.05
2.00
1.95
1.90
1.85
7.7
7.6
7.5
7.4
7.3
7.2
 PIPING LENGTH (m)
52515 2010
220V
240V 
I:                                                  Q:
Current (A)                           
-    Heating Capacity  (kW)                                -
LP:                                                              O: Outlet
Gas Side Piping Pressure (MPa)                    Air Temperature (°C)                 
[Condition]  Room temperature: 20°C
                   Outdoor temperature: 7/6°C
                   Heating operation: High fan
I
LP
Q
O
Untitled-4 6/21/00, 10:40 AM40