ITEM / MODEL
CS-A24BB4P, CU-A24BBP5
Condition by JIS B 8615
Volts V 220 230
240
Phase Single Single
Single
Power Consumption kW Cool 2.50 2.50
2.50
Heat 2.49 2.49
2.49
Running Current A Cool 11.5 11.1
10.7
Heat 11.4 11.0
10.7
Starting Current A 49 51 52
Power Factor % Cool 99 98 97
Heat 99 98 97
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic Power source AC, 1~220V, 230V, 240V
50Hz
3.2. CS-A28BB4P / CU-A28BBP5
ITEM / MODEL
Indoor Unit Outdoor
unit
Main Body CS-A28BB4P CU-
A28BBP5
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL51P (Wireless)
Cooling Capacity kW 7.1
BTU/h 24,200
Heating Capacity kW 8.0
BTU/h 27,300
Refrigerant Charge-less m 30
Standard Air Volume for High,
m
3
/min
Hi 20 Me 18 Lo 16 Hi 43
Medium and Low Speed cfm 706 635 565 1518
Outside Dimension (H x W x D) mm 240 x 840 x 840 900 x 900
x
inch 9-7/16 x 33-1/24 x 33-1/24 35-7/16 x 35-7/16
x
Net Weight kg 26 82
lbs 57 181
Piping
Connection
Refrigerant Gas mm (inch) O.D Ø 15.88 (5/8) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20
x
Compressor
Type, Number of Set - Hermetic-1 (
Rotary),
Starting Method - Direct on-line
starting
Motor Type - 2-pole single
phase
induction
motor
Input kW - Cool/Heat
Rated
Output
kW - 2.0
12

Other manuals for Panasonic CS-A24BB4P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-A24BB4P and is the answer not in the manual?

Panasonic CS-A24BB4P Specifications

General IconGeneral
BrandPanasonic
ModelCS-A24BB4P
CategoryAir Conditioner
LanguageEnglish

Related product manuals