Operation
Details
8)
Airflow
Direction
Control
|
Airflow
Direction
Auto-Control
e
When
set
a
Airflow
Direction
Auto-Control
with
Horizontal
remote
control,
the
louver
swings
up
and
down
as
~
shown
in
the
diagram.
¢
The
louver
does
not
swing
when
the
Indoor
Fan
stops
during
operation.
Swing
up
and
down
e
When
stopped
with
remote
control,
the
discharge
ieswen
trate
tor
vent
is
closed
with
the
louver.
Cooling
Mode
and
Soft
Dry
Mode
upper
limit
Lower
limit
for
Heating
Mode
*X
The
left
and
right
airflow
direction
louvers
can
be
adjusted
manually.
><1_
There
is
no
swinging
while
indoor
fan
is
stopped
during
Cooling
and
Soft
Dry
operation.
<2.
In
Heating
operation,
when
the
indoor
heat
exchanger
temperature
rises
to
38°C,
the
airflow
direction
is
changed
from
upper
limit
to
lower
limit.
When
the
indoor
heat
exchanger
temperature
falls
to
35°C,
the
airflow
direction
is
changed
from
lower
limit
to
upper
limit.
Airflow
Direction
Manual
Control
e
When
the
airflow
direction
set
button
is
pressed,
the
automatic
airflow
is
released
and
the
airflow
direction
louver
move
up
and
down
in
the
range
shown
in
the
diagram.
Horizontal
The
louver
can
be
stopped
by
releasing
the
button
upper
limit
at
the
desired
louver
position.
e
When
the
remote
control
is
used
to
stop
the
opera-
tion,
the
discharge
vent
is
closed
with
airflow
direction
louver.
Lower
limit
for
Cooling
Mode
and
Soft
Dry
Mode
Lower
limit
for
Heating
Mode
The
louver
can
be
adjusted
with
in
a
range
“Airflow
Direction
Setting
Button”
is
pressed.
The
left
and
right
airflow
direction
louvers
can
be
adjusted
manually.
9)
Delay
ON
Timer
Control
°
When
the
Delayed
ON
Timer
is
set
by
using
the
remote
control,
the
unit
will
start
operate
slightly
before
the
set
time,
so
that
the
room
will
reach
nearly
to
the
set
temperature
by
the
desired
time.
°
For
Cooling
and
Soft
Dry
mode,
the
operation
will
start
15
minutes
before
the
set
time.
¢
For
Heating
mode,
the
operation
will
start
30
minutes
before
the
set
time.
*
For
Automatic
mode,
the
indoor
fan
will
operate
at
SLo
speed
for
20
seconds
30
minutes
before
the
set
time
to
detect
the
intake
air
temperature
to
determine
the
operation
mode.
The
operation
indication
lamp
will
blink
at
this
time.
2
O75