68
(Heating Operation condition)
• When Powerful operation is set, the setting temperature will be automatically increased 3°C against the present
setting temperature (Higher temperature: 30°C).
• The Fan Speed will shift as shown below:
• Vertical Airflow Direction:-
o In “Manual” setting, the vane will automatically shift down 5° lower than previous setting.
o In “Auto” setting, the vane will automatically shift between upper and lower limit depending on the intake air
temperature as Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be
shifted 5° downward.
• Powerful operation stops when:-
o Powerful operation has operate for 4 hours.
o Powerful button is pressed again.
o Quiet button is pressed
o Stopped by OFF/ON operation button.
o Timer OFF activates.
o Operating mode is changed.