EasyManuals Logo

Panasonic CS-A9PKD Service Manual

Panasonic CS-A9PKD
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
75
13.16 AUTO COMFORT and ECONAVI Operation
AUTO COMFORT start condition:
o When AUTO COMFORT button is pressed.
AUTO COMFORT stop conditions:
o When AUTO COMFORT button is pressed again.
o When unit is OFF by OFF/ON button.
o When unit is OFF when OFF TIMER activates.
o When unit is OFF by AUTO OFF/ON button at indoor unit.
o When POWERFUL, QUIET operation activates.
o When ◄► button is pressed.
ECONAVI start condition:
o When ECONAVI button is pressed.
ECONAVI stop conditions:
o When ECONAVI button is pressed again.
o When unit is OFF by OFF/ON button.
o When unit is OFF when OFF TIMER activates.
o When unit is OFF by AUTO OFF/ON button at indoor unit.
o When POWERFUL, QUIET operation activates.
o When ◄► button is pressed.
13.16.1 Human Activity Sensor
Area of human availability, activity level and absent is judged based on pulses by using 2 infrared sensors. The
internal setting temperature shift, fan speed and horizontal airflow direction are adjusted in order to provide
comfort environment while maintain the energy saving level.
AUTO COMFORT / ECONAVI initialization
Initialize indication Human Activity Sensor
1 0 – 2 seconds
2 2 – 3 seconds
I
II
III
IV
3 3 – 70 seconds
Repeat Step I to IV
* Indicator ON, Indicator OFF
Human activity judgment is as following

Table of Contents

Other manuals for Panasonic CS-A9PKD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-A9PKD and is the answer not in the manual?

Panasonic CS-A9PKD Specifications

General IconGeneral
BrandPanasonic
ModelCS-A9PKD
CategoryAir Conditioner
LanguageEnglish

Related product manuals