7  Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoor 
unit according to the diagram below. 
 
 
 
8  Secure the power supply cord and connection cable onto the control board with the holder. 
9  Close grille door by tighten with screw and close the front panel. 
 
Note: 
  Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap. 
  Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively. 
  Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires as shown in the figure for the 
electrical safety in case of the slipping out of the cord from the anchorage. 
11.2.4.1  Wire Stripping and Connecting Requirement  
 
 
 
 
 
 
 
 
 
 
3
2
1
ti
nu
 
r
o
o
dtuo eht
 
n
o
 
s
l
a
n
i
m
reT
Colour of wires (connection cable)
Terminals on the indoor unit
LN123
(Power supply cord)
Terminals on the isolating devices 
(Disconnecting means)
(L) (N)
Recommended 
length (mm)
abcdefg
55 35 35 50 40 35 60
 WARNING
 This equipment must 
be properly earthed.
Recommended 
length (mm)
Tap e
Connection cable
Tape
Power supply cord
Terminal Board
Control 
Board
Earth wire 
longer than 
others 
AC wires 
for safety 
reason
Holder
Holder
Indoor & outdoor 
connection cable 
Isolating Devices
Outdoor unit
Power supply 
cord
OR
OR
OR
  Do not joint wires
  Use complete wire without joining.
  Use approved socket and plug with earth pin.
 
Wire connection in this area must follow to national wiring rules.
Conductor 
over inserted
Wire stripping
No loose strand 
when inserted
10 ± 1 mm
Conductor 
fully inserted
PROHIBITED
Conductor not 
fully inserted
PROHIBITED
ACCEPT
Indoor/outdoor 
connection 
terminal board
5 mm or more 
(gap between wires)
WARNING
RISK OF FIRE
JOINING OF WIRES 
MAY CAUSE 
OVERHEATING AND 
FIRE.