Cooling or Soft Dry Operation
Purpose is to obtain a comfortable room temperature while
sleeping. When you press the SLEEP Mode, the following
movement will start to avoid overcooling.
Sleep shift operation starts, when the room temperature
reaches the setting temperature or after 1 hour of operation.
The setting temperature will be risen by 0.5°C at the start of
operation and by 0.5°C one hour later.
The airflow volume will automatically change to Low fan
speed.
Sleep Mode operation time is 8 hours, the operation will be
stop after 8 hours.
When used together with the Timer, the Timer has priority.
8.5. Sleep Mode Auto Operation
8.6. Powerful Mode Operation
Purpose of this operation is to obtain the setting temperature quickly.
When the Powerful Mode is set, the set temperature will be automatically decreased 3°C against the present setting
temperature (Lower temperature: 16°C).
This operation automatically will be running under SHi Fan Speed (Cooling), SLo Fan Speed (Soft Dry).
Vertical Airflow Direction:-
-InManual setting, the vane will automatically swing down 10° lower than previous setting.
-InAuto setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.
Powerful Mode will operate for 15 minutes only, after that it will shift back to previous operation mode.
Powerful Mode will stop if:-
- Powerful mode button is pressed again.
- Stopped by ON / OFF switch.
- Timer OFF activates.
- Economy mode button is pressed.
- Sleep mode is pressed.
- Operation mode button is changed.
8.7. Economy Mode Operation
Purpose of this operation is to save or reduced electrical power consumption of the room air conditioner.
When the Economy Mode is set, the set temperature will be automatically increased 0.5°C against the preset setting
temperature (Higher temperature: 30°C).
This operation automatically will be running under SLo Fan Speed.
Vertical Airflow Direction:-
In Manual or Auto setting, the vane will automatically change to Auto Air Swing.
Economy Mode will stop if:-
- Economy Mode button is pressed again.
- Stopped by ON / OFF switch.
- Timer OFF activates.
- Powerful mode button is pressed.
- Auto or Manual air swing button is pressed.
- Fan Speed control button is pressed.
- Sleep Mode button is pressed ON.
- Operation Mode is changed.
24
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6

Other manuals for Panasonic CS-C18BKP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-C18BKP and is the answer not in the manual?

Panasonic CS-C18BKP Specifications

General IconGeneral
BrandPanasonic
ModelCS-C18BKP
CategoryAir Conditioner
LanguageEnglish

Related product manuals