– 35 –
MAC9512086C2
CS-C181KE
Technical Data
LL
LL
L Thermostat characteristics
CS-C181K / CS-C241K
• Cooling
• Soft Dry
/                             
Cooling ON
/                           
/                                        
Diff. 1.5°C
16
16
(°C)
Intake Air Temperature
 
/                          
Soft Dry OFF, Soft Dry ON
/                                        
Diff. 1.0°C
Thermostat Setting (Remote Control)
34
24
22
20
18
28
26
30
32       
18 20
22
24
26
28 30 (°C)  
/
/
 
Cooling OFF = Set Temperature
16
16
(°C)
Thermostat Setting (Remote Control) 
Intake Air Temperature
/                         
COMP. OFF = Set Temperature
/                         
COMP. ON
18 28
2624
2220
30
18
20
22
24
26
28
30     
32
34
(°C)
/                                       
Diff. 1.5°C
/
/
Untitled-7 6/19/00, 5:31 PM35